CANTILEVER IN PROSTHESIS: EVALUATION OF RELATION BETWEEN THICKNESS AND LENGTH WITH LOADING IN Ni-Cr BARS

GENNARI, HUMBERTO and GOIATO, MARCELO COELHO and ZUIM, PAULO RENATO JUNQUEIRA and MAZARO, JOSÉ VITOR QUINELI and SILVA, CRISTINA RAMOS DA (2015) CANTILEVER IN PROSTHESIS: EVALUATION OF RELATION BETWEEN THICKNESS AND LENGTH WITH LOADING IN Ni-Cr BARS. Journal of Basic and Applied Research International, 10 (3). pp. 95-101.

Full text not available from this repository.

Abstract

Aim: The aim of this study was to evaluate the relation between the applied force and deformation in Nickel-Chromium-Molybdenum-Titanium alloy bars with different cantilever thicknesses and lengths in a universal mechanical testing machine.

Methods: Sixty metallic Nickel-Chromium-Molybdenum-Titanium alloy (Ni-Cr-Mo-Ti) bars, 40 mm in length, were divided into 4 groups with thicknesses of 4.0, 3.5, 3.0, and 2.5 mm. All bars were submitted to compressive loading of 200 kgf in a universal mechanical testing machine at a frequency of 0.5 mm per minute. The loads were applied automatically and gradually in a cantilever length of 10, 15 and 20 mm until alloy fatigue. The method was controlled by software to indicate the relation between the applied force and deformation. Data were submitted to an analysis of variance and Tukey`s test.

Results: The analysis of variance revealed statistically significant differences in the individual evaluation of thickness and length and also in the relation between the thickness and length (p<0.01).

Item Type: Article
Subjects: Eprint Open STM Press > Multidisciplinary
Depositing User: Unnamed user with email admin@eprint.openstmpress.com
Date Deposited: 11 Dec 2023 04:52
Last Modified: 11 Dec 2023 04:52
URI: http://library.go4manusub.com/id/eprint/1897

Actions (login required)

View Item
View Item